BOX-AM10-1800

Designed to reach 1800 ˚C and maintain temperature at 1750 ˚C continuously

1800°C

BOX-AM10-1800 models being able to reach 1800 °C and maintain temperature at 1750 °C  continuously, represent ultra high temperature chamber furnaces. These models are equipped with high-quality KANTHAL Super MoSi2 resistors which are known for their long working life under oxidizing atmospheres. They are resistant to thermal shock and can withstand very high power loads, making them ideal for extremely fast temperature ramping processes. 

Ordering Info

Standard Features and Specifications

Optional Features

Technical Data

Model Part Number Heated Volume Liters Nominal Max. Power (W)/No. of Resistors
Model Part Number
BOX-AM10-V3-1800
Heated Volume Liters
3
Nominal Max. Power (W)/No. of Resistors
3000/2
Model Part Number
BOX-AM10-V4-1800
Heated Volume Liters
4
Nominal Max. Power (W)/No. of Resistors
4800/4
Model Part Number
BOX-AM10-V6-1800
Heated Volume Liters
6
Nominal Max. Power (W)/No. of Resistors
6200/6
Model Part Number
BOX-AM10-V8-1800
Heated Volume Liters
8
Nominal Max. Power (W)/No. of Resistors
7200/6
Model Part Number
BOX-AM10-V16-1800
Heated Volume Liters
16
Nominal Max. Power (W)/No. of Resistors
9600/6

Important Ordering Notes

  • Control strategy based on Thermansys® PCC (Power Consistent Control) platform insures silent operation and compliance with EMC standards.
  • Modern double wall construction keeps external surfaces temperature low.Internal skin is exclusively made from stainless steel to enhance durability.
  • Heater failure, open control thermocouple detection, door open alarms and interlocks. Alarms and events front panel led array.
  • Optional Touch Screen Computer running PYROLOGISM 2.0 software human-machine interface.
  • Power and true RMS Current measuring circuits.
  • Stand alone over-temperature limiter (Watchdog) with manual reset in accordance with EN 60519-2 to protect the oven and load. Overrides main controller and cut off heater power if user adjustable high limit is reached.
  • Lift up door keep hot surfaces away from operator.